I. overview
This series of water meters consists of pilot piston globe valve and removable horizontal screw-wing water meter.
II. Technical parameters
Temperature grade: T30
Pressure Level: MAP10
Pressure Loss: Pilot Piston Globe Valve: Pressure Loss < 0.08MPa under Overload Flow
Removable horizontal screw-wing water meter: P25
Sensitivity level of upstream flow field: U10
Sensitivity level of downstream flow field: D5
Valve Voltage, Current and Switching Time of Pilot Piston Valve
Voltage: DC 3.6V Current: 60mA Switch Valve Time: 7S
3. Shape size